Biolight M1000 Vet 8" Vet Multi-Parameter Touchscreen Quality Compact Monitor
Regular price
$1274.15
Regular price
Sale price
$1274.15
Biolight M1000 Vet 8" Vet Multi-Parameter Touchscreen Compact Monitor
High quality monitor, made by BLT Biolight; very accurate and reliable.
Comes with veterinary accessories, and ready for the work.
It is small, only a few pounds, and does not take much of the space.
Standard configuration:
3/5 Lead ECG, HR, RESP, NIBP, SpO2, PR, TEMP, Rechargeable lithium ion battery.
- 8” TFT LCD touch screen
- Lightweight and compact portable design
- Standard parameters including 3/5 leads ECG, HR, RESP, NIBP, SpO2, PR, TEMP
- Triple and Multi-level Sound/Light/Screen alarm
- Large capability battery with over 6 hours continuous usage
- 168 hours trend data storage
- 1000 groups NIBP measurement review
Physical & Power specifications
Dimension: 220mm (H)×180mmW)×90mm(D)
Weight: <2 kg
Power Voltage: AC 100V-240V 50Hz/60Hz
Input current: 1.5A-0.7A
Battery
Type: 11.1VDC/2200mAh, Rechargeable Lithium ion battery
Operating time: Under the normal use and full charge: ≥6 hours
Indicator of battery capability: With
Display
Size: 8″ Color TFT LCD touch screen
Resolution: 800×600 pixels
Data Storage
Trend data: 168 Hours
NIBP measurement review: 1000 Groups
Alarm Events: 128 Groups
ARR event: 128 Groups
ECG
Lead Mode: 3/5 leads ECG input
Lead selection: I, II, III, aVR, aVL, aVF, V
Gain: 2.5 mm/mV(×0.25), 5 mm/mV(×0.5),
10 mm/mV(×1),20 mm/mV(×2) ,
40 mm/mV(×4) , Auto
Input impedance: ≥5.0 MΩ
Animal leakage current: < 10 uA
CMRR : Diagnostic mode ≥ 89 dB
Monitor mode ≥ 105 dB
Surgery mode ≥ 105 dB
Baseline recovery: Monitor mode: ≤ 3 s;
Surgery mode: ≤ 1 s
Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
HR
Measurement Range: Large animal: 10 bpm to 300 bpm
Normal and small animal: 10 bpm to 350 bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
RESP
Method: Thoracic impedance
Measuring impedance range: 0.2Ω ~3Ω
Accuracy: ±2 rpm
NIBP
Measurement way: Automatic Oscillometry
Measurement range(mmHg): SYS 30~270 mmHg
DIA 10~220 mmHg
Map 20~235 mmHg
(Large animal, normal and small animal have different measurement range)
Pressure Accuracy: Static: ±3 mmHg
Clinic: Average error: ±5 mmHg,
standard deviation: ≤8 mmHg
Unit: mmHg, kPa
Cuff pressure range: 0 mmHg ~ 280 mmHg
Initial inflation pressure:
Large animal default: 160 mmHg
Mid animal default: 130 mmHg
Small animal default: 75 mm
Overpressure Protection(Hardware and software double protections):
Large animal: (297±3) mmHg Normal animal: (147±3) mmHg
Small animal: (252±3) mmHg
Alarm Indication: Three levels of alarming: Audible-visual alarming
Alarming with blinked data and parameters Text prompts
Work mode: Large animal: Single, Cycle, STAT
Normal animal: Single, Cycle, STAT
Small animal: Single, Cycle
BLT SpO2
Measurement Range: 0%~100%
Resolution: 1%
Accuracy: At 70~100%, ±2% At 0~69%, unspecified
Alarm range: 85% to 100%, high/low limit can be adjusted continuously
Average time: Normal:8s, slow: 16s,fast: 4s
Anti-interference: Anti-interference of movement Anti-interference of electrocautery unit
Resisting low perfusion capability
Pitch Tone: With
PR
Measurement Range: 20~250 bpm
Resolution:1 bpm Accuracy: ±1% or ±1 bpm, whichever is greater
Alarm range: 0 bpm~300 bpm, high/low limit can be adjusted continuously
Recovery time after defibrillation: <10s
TEMP
Measurement way: Thermal resistance way
Measurement Range: 0.0~50.0℃ (32℉~122℉)
Unit : Celsius (℃), Fahrenheit (℉)
Resolution: 0.1℃
Accuracy: At 45.1~50.0℃, ±0.3℃ (including the probe)
At 25.0~45.0℃, ±0.2℃ (including the probe)
At 0.0~24.9℃, ±0.3℃ (including the probe)
KeeboMed, Inc.
Mount Prospect, IL USA
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Authorized purchasers only. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.