Biolight M1000 Vet 8" Vet Multi-Parameter Touchscreen Compact Monitor
High quality monitor, made by BLT Biolight; very accurate and reliable.
Comes with veterinary accessories, and ready for the work.
It is small, only a few pounds, and does not take much of the space.
Standard configuration:
3/5 Lead ECG, HR, RESP, NIBP, SpO2, PR, TEMP, Rechargeable lithium ion battery.
- 8” TFT LCD touch screen
- Lightweight and compact portable design
- Standard parameters including 3/5 leads ECG, HR, RESP, NIBP, SpO2, PR, TEMP
- Triple and Multi-level Sound/Light/Screen alarm
- Large capability battery with over 6 hours continuous usage
- 168 hours trend data storage
- 1000 groups NIBP measurement review
Physical & Power specifications
Dimension: 220mm (H)×180mmW)×90mm(D)
Power Voltage: AC 100V-240V 50Hz/60Hz
Type: 11.1VDC/2200mAh, Rechargeable Lithium ion battery
Operating time: Under the normal use and full charge: ≥6 hours
Indicator of battery capability: With
Size: 8″ Color TFT LCD touch screen
Resolution: 800×600 pixels
NIBP measurement review: 1000 Groups
Lead Mode: 3/5 leads ECG input
Lead selection: I, II, III, aVR, aVL, aVF, V
Gain: 2.5 mm/mV(×0.25), 5 mm/mV(×0.5),
10 mm/mV(×1),20 mm/mV(×2) ,
Animal leakage current: < 10 uA
CMRR : Diagnostic mode ≥ 89 dB
Baseline recovery: Monitor mode: ≤ 3 s;
Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
Measurement Range: Large animal: 10 bpm to 300 bpm
Normal and small animal: 10 bpm to 350 bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
Method: Thoracic impedance
Measuring impedance range: 0.2Ω ~3Ω
Measurement way: Automatic Oscillometry
Measurement range(mmHg): SYS 30~270 mmHg
(Large animal, normal and small animal have different measurement range)
Pressure Accuracy: Static: ±3 mmHg
Clinic: Average error: ±5 mmHg,
standard deviation: ≤8 mmHg
Cuff pressure range: 0 mmHg ~ 280 mmHg
Initial inflation pressure:
Large animal default: 160 mmHg
Mid animal default: 130 mmHg
Small animal default: 75 mm
Overpressure Protection(Hardware and software double protections):
Large animal: (297±3) mmHg Normal animal: (147±3) mmHg
Small animal: (252±3) mmHg
Alarm Indication: Three levels of alarming: Audible-visual alarming
Alarming with blinked data and parameters Text prompts
Work mode: Large animal: Single, Cycle, STAT
Normal animal: Single, Cycle, STAT
Small animal: Single, Cycle
Measurement Range: 0%~100%
Accuracy: At 70~100%, ±2% At 0~69%, unspecified
Alarm range: 85% to 100%, high/low limit can be adjusted continuously
Average time: Normal:8s, slow: 16s,fast: 4s
Anti-interference: Anti-interference of movement Anti-interference of electrocautery unit
Resisting low perfusion capability
Measurement Range: 20~250 bpm
Resolution:1 bpm Accuracy: ±1% or ±1 bpm, whichever is greater
Alarm range: 0 bpm~300 bpm, high/low limit can be adjusted continuously
Recovery time after defibrillation: <10s
Measurement way: Thermal resistance way
Measurement Range: 0.0~50.0℃ (32℉~122℉)
Unit : Celsius (℃), Fahrenheit (℉)
Accuracy: At 45.1~50.0℃, ±0.3℃ (including the probe)
At 25.0~45.0℃, ±0.2℃ (including the probe)
At 0.0~24.9℃, ±0.3℃ (including the probe)