Biolight M1000 Vet 8" Vet Multi-Parameter Touchscreen Quality Compact Monitor

Save $ 229.35

Price:
Sale price$ 1,044.80 Regular price$ 1,274.15

Description

Biolight M1000 Vet 8" Vet Multi-Parameter Touchscreen Compact Monitor


High quality monitor, made by BLT Biolight; very accurate and reliable.
Comes with veterinary accessories, and ready for the work.
It is small, only a few pounds, and does not take much of the space.
Standard configuration:
3/5 Lead ECG, HR, RESP, NIBP, SpO2, PR, TEMP, Rechargeable lithium ion battery.
  • 8” TFT LCD touch screen 
  • Lightweight and compact portable design 
  • Standard parameters including 3/5 leads ECG, HR, RESP, NIBP, SpO2, PR, TEMP 
  • Triple and Multi-level Sound/Light/Screen alarm 
  • Large capability battery with over 6 hours continuous usage 
  • 168 hours trend data storage 
  • 1000 groups NIBP measurement review
Physical & Power specifications
Dimension: 220mm (H)×180mmW)×90mm(D) 
Weight: <2 kg 
Power Voltage: AC 100V-240V 50Hz/60Hz 
Input current: 1.5A-0.7A
Battery 
Type: 11.1VDC/2200mAh, Rechargeable Lithium ion battery 
Operating time: Under the normal use and full charge: ≥6 hours 
Indicator of battery capability: With
Display
Size: 8″ Color TFT LCD touch screen 
Resolution: 800×600 pixels
Data Storage
Trend data: 168 Hours 
NIBP measurement review: 1000 Groups 
Alarm Events: 128 Groups 
ARR event: 128 Groups
ECG
Lead Mode: 3/5 leads ECG input 
Lead selection: I, II, III, aVR, aVL, aVF, V 
Gain: 2.5 mm/mV(×0.25), 5 mm/mV(×0.5), 
 10 mm/mV(×1),20 mm/mV(×2) ,  
 40 mm/mV(×4) , Auto 
Input impedance: ≥5.0 MΩ 
Animal leakage current: < 10 uA 
CMRR : Diagnostic mode ≥ 89 dB
Monitor mode ≥ 105 dB 
Surgery mode ≥ 105 dB 
Baseline recovery: Monitor mode: ≤ 3 s; 
Surgery mode: ≤ 1 s 
Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
HR 
Measurement Range: Large animal: 10 bpm to 300 bpm 
Normal and small animal: 10 bpm to 350 bpm 
Accuracy: ±1% or ±1 bpm, whichever is greater
RESP 
Method: Thoracic impedance 
Measuring impedance range: 0.2Ω ~3Ω 
Accuracy: ±2 rpm
NIBP 
Measurement way: Automatic Oscillometry 
Measurement range(mmHg): SYS 30~270 mmHg 
 DIA 10~220 mmHg  
 Map 20~235 mmHg 
(Large animal, normal and small animal have different measurement range) 
Pressure Accuracy: Static: ±3 mmHg 
Clinic: Average error: ±5 mmHg, 
standard deviation: ≤8 mmHg 
Unit: mmHg, kPa 
Cuff pressure range: 0 mmHg ~ 280 mmHg
Initial inflation pressure:
Large animal default: 160 mmHg 
Mid animal default: 130 mmHg 
Small animal default: 75 mm 
Overpressure Protection(Hardware and software double protections): 
Large animal: (297±3) mmHg Normal animal: (147±3) mmHg 
Small animal: (252±3) mmHg 
Alarm Indication: Three levels of alarming: Audible-visual alarming 
Alarming with blinked data and parameters Text prompts 
Work mode: Large animal: Single, Cycle, STAT 
Normal animal: Single, Cycle, STAT 
Small animal: Single, Cycle
BLT SpO2 
Measurement Range: 0%~100% 
Resolution: 1% 
Accuracy: At 70~100%, ±2% At 0~69%, unspecified 
Alarm range: 85% to 100%, high/low limit can be adjusted continuously
Average time: Normal:8s, slow: 16s,fast: 4s 
Anti-interference: Anti-interference of movement Anti-interference of electrocautery unit 
Resisting low perfusion capability 
Pitch Tone: With
PR 
Measurement Range: 20~250 bpm 
Resolution:1 bpm Accuracy: ±1% or ±1 bpm, whichever is greater 
Alarm range: 0 bpm~300 bpm, high/low limit can be adjusted continuously 
Recovery time after defibrillation: <10s
TEMP 
Measurement way: Thermal resistance way 
Measurement Range: 0.0~50.0℃ (32℉~122℉) 
Unit : Celsius (℃), Fahrenheit (℉) 
Resolution: 0.1℃ 
Accuracy: At 45.1~50.0℃, ±0.3℃ (including the probe) 
At 25.0~45.0℃, ±0.2℃ (including the probe) 
At 0.0~24.9℃, ±0.3℃ (including the probe)

KeeboMed, Inc.    

Mount Prospect, IL  USA  

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Authorized purchasers only. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.

You may also like