Mindray iMEC-8Vet Portable Veterinary Monitor with EtCO2
Features
- 8.4" High-resolution LED display with 8 waveforms
- Portable, less than 3.2 kg
- No-fan design for a quiet care environment
- Easy to use for intuitive operation
- Up to 4 hours continuous monitoring with large capacity Li-ion battery
- Trust for veterinary use, parameters including ECG, RESP, SpO2 , NIBP, PR, TEMP, IBP, CO2
- 360-degree visible alarm indicator
- 120 hours trend and 48 hours waveforms reviewing
Standard Configuration
- ECG
- RESP
- NIBP
- Mindray SpO2
- TEMP
- Li-ion battery
Specifications
- Weight: ≤3.2 kg (8.5 lb)
- Size: <210 x 270 x 112 mm (8.3 x 10.6 x 4.4 inch)
- Display: 8.4" high-resolution LED with 800 x 600 pixels
- Waveforms: Up to 8 traces
- ECG: 5 or 3 lead: I, II, III, aVR, aVL, aVF, V
- Respiration: RA-LA/RA-LL Impedance
- SpO2: Masimo SET, Nellcor Oximax
- NIBP: Manual, Auto, STAT
- Temperature: 2 channels
- Recorder: 3-trace thermal array, 50 mm
- Reviewing:
- 120 hours trends
- 100 alarm events and associated waveforms
- 1000 groups NIBP
- Up to 48 hours waveforms
- Download to PC: USB
- Video Output: 1VGA
- Wired Network: 1 RJ45
ECG
- RR Range: 15 - 350 bpm
- Speed: 6.25/12.5/25/50 mm/s
- ECG Gain: 1.25/2.5/5/10/20/40 mm/mV, Auto Sweep
- Mode: Diagnostic, Monitor, or Surgical
PR Range
- 25 to 240 bpm (Masimo SpO2)
- 20 to 300 bpm (Nellcor SpO2)
- 25 to 350 bpm (IBP)
- 40 to 240 bpm (NIBP)
NIBP Range
- Systolic 40 to 270 mmHg
- Diastolic 10 to 210 mmHg
- Mean 20 to 230 mmHg
- Interval in Auto Mode:
- 1/2/2.5/3/5/10/15/20/30/60/90/120/180/240/ 480min
- Max Time Allowed: 180 s
Respiration
- Lead: I, II or Auto
- RR Range: 0 to 150 rpm
- Accuracy: 7 to 150 rpm: ±2 rpm or ±2%, whichever is greater
Nellcor Oximax SpO2
- Measurement Range: 20-300 bpm
- Accuracy:
- 20 to 250 bpm: ±3 bpm
- 251 to 30 bpm: not specified
Masimo SET SpO2
- Measurement Range: 25-240 bpm
- Accuracy:
- ±3 bpm (measured without motion)
- ±5 bpm (measured without motion)
C.O.
- Range:
- C.O.: 0.1 to 20 L/min
- TB: 23 to 43°C
- TI: 0 to 27°C
- Accuracy:
- C.O.: ±5% or ±0.1 L /min whichever is greater
- TB, TI: ±0.1°C (without sensor)
- Resolution:
- C.O.: 0.1 L/min
- TB, TI: 0.1°C
IBP
- Range: -50 to 300 mmHg
- Accuracy: ±2% or±1mmHg whichever is greater
EtCO2 - Sidestream
- Sample Rate: 70 /100 ml/min
- Range: 0 to 99 mmHg
- awRR Range: 0 to 120 rpm
- Accuracy:
- 0 to 40 mmHg, ±2 mmHg
- 41 to 76 mmHg, ±5% of the reading
- 77 to 99 mmHg, ±10% of the reading
EtCO2 - Mainstream
- Range: 0 to 150 mmHg
- awRR Range: 0 to 150 rpm
- Accuracy:
- 0 to 40 mmHg, ±2 mmHg
- 41 to 70 mmHg, ±5% of the reading
- 101 to 150 mmHg, ±10% of the reading
- 71 to 100 mmHg, ±8% of the reading
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.